меню

10-Second ATP Hygiene Monitoring System for Food Plant Cleaning Verification

в наличии:
SKU: 4729110102
модель: Biolum Plus

{{ variable.name }}

{{ value.name }}
Biolum Plus ATP luminometer reference view for food plant cleaning verification
10 s per test10-18 mol ATPWiFi cloud dataAOAC PTM 022401

10-Second ATP Hygiene Monitoring System for Food Plant Cleaning Verification

Biolum Plus is a portable ATP luminometer for surface and liquid hygiene monitoring on food processing lines, with handheld operation and cloud-based data management over WiFi.

Product Summary

Biolum Plus is a portable ATP luminometer from Tianlong, built for surface and liquid hygiene monitoring in food processing plants. Sanitation teams use it to check organic residue on food-contact surfaces and equipment after cleaning, with a 10-second test cycle and a published detection limit of 10-18 mol ATP. Each test returns an automatic Pass, Caution or Fail result, and readings can be sent over USB, Bluetooth or WiFi to a cloud-based data management platform. At 315 g and 189 × 70 × 35 mm the instrument is carried along the line and into wash-down areas, while the rechargeable battery supports routine indoor rounds between 5 °C and 40 °C.

Key Features

10 seconds per testA 10-second test cycle lets the sanitation team sample more contact surfaces inside the same cleaning window instead of waiting for laboratory turnaround.
10-18 mol ATP detection limitThe published detection limit supports verification of organic residue on food-contact surfaces and processing equipment after wash-down.
315 g handheld unitAt 189 × 70 × 35 mm and 315 g, the instrument is carried one-handed along conveyors, fillers and equipment platforms during a cleaning round.
WiFi, Bluetooth and USB transferReadings move to a cloud-based data management platform, so QA and sanitation managers review cleaning verification records without collecting the devices.
10,000 results and 2,000 test programs256 test plans and 256 user IDs let one instrument serve several lines, shifts and operators while keeping their sampling plans separate.
AOAC Research Institute PTM 022401The certificate scope covers the luminometer and matched ATP test swabs, giving buyers a documented method reference (issued 17 July 2026, valid to 31 December 2026).

Technical Specifications

ParameterSpecification
ModelBiolum Plus
Product typePortable ATP luminometer, surface and liquid hygiene monitoring
Detection limit10-18 mol ATP
Detection time10 s per test
Result displayAutomatic Pass / Caution / Fail
Weight315 g
Dimensions189 × 70 × 35 mm
CommunicationUSB, Bluetooth, WiFi
Memory256 test plans; 256 user IDs; 2,000 test programs; 10,000 results
Power supplyRechargeable battery
Operating temperature5–40 °C
CertificationAOAC Research Institute Performance Tested Methods, certificate 022401 (issued 17 July 2026, valid to 31 December 2026), covering the luminometer and matched ATP test swabs

Models and Options

Biolum Plus is the model described on this page. A complete test routine also uses the matched consumables and the data layer listed below.

  • Biolum Plus portable ATP luminometer, as specified in the table above
  • Matched ATP test swabs for surface and liquid sampling, plus a calibration swab
  • Cloud-based data management platform reached over WiFi, with USB and Bluetooth also available

Tianlong also lists Biolum and Biolum Pro ATP systems in its product portfolio. Those models are not specified in the materials behind this page, so contact the team for the current configuration of each model before comparing them.

Materials and Structure

The instrument is a handheld unit of 189 × 70 × 35 mm weighing 315 g, powered by a rechargeable battery and rated for indoor operation from 5 °C to 40 °C. Communication runs over USB, Bluetooth and WiFi. A test uses a matched ATP test swab taken from the surface or liquid sample; the device runs a 10-second cycle and returns an automatic Pass, Caution or Fail reading.

Applications

  • Food processing: cleaning verification on food-contact surfaces, conveyors, fillers and preparation tables before production restarts
  • Food service: routine hygiene checks on work surfaces and equipment
  • Healthcare hygiene: surface monitoring where organic residue control is part of the cleaning routine
  • Environmental hygiene: scheduled indoor surface checks, with results uploaded to the cloud platform

Customization

Sampling structure is set on the device: up to 256 test plans, 256 user IDs and 2,000 test programs can be organised by line, shift, operator or sampling point, and 10,000 results are stored for later review. Sampling points, site names and test frequency follow your own sanitation plan rather than the instrument, so the team can review your plan requirements before a quotation. Consumable selection and cloud platform setup can be discussed through the inquiry channels below.

FAQ

How long does one ATP test take?
About 10 seconds per test, so a cleaning round can cover many surfaces without laboratory turnaround.
How sensitive is Biolum Plus?
The published detection limit is 10-18 mol ATP.
Can the system test liquids as well as surfaces?
Yes. It is described as a surface and liquid hygiene monitoring system, using matched ATP test swabs for sampling.
How do results reach the quality team?
Readings transfer over USB, Bluetooth or WiFi to a cloud-based data management platform, and the instrument stores up to 10,000 results locally.
What does the device show after a test?
An automatic Pass, Caution or Fail result for each sample, based on the measured ATP signal.
What are the operating conditions?
Indoor use between 5 °C and 40 °C, powered by a rechargeable battery.
Which certification applies to the system?
AOAC Research Institute Performance Tested Methods certification, certificate 022401, issued 17 July 2026 and valid to 31 December 2026, covering the luminometer and matched ATP test swabs.
How many sampling plans can one device hold?
256 user IDs and 256 test plans, together with 2,000 test programs and storage for 10,000 results.

Inquiry Information

Send sampling points, line details and reporting requirements for a configuration check and quotation.

Email: inquiry@medtl.com
Telephone: +86-29-82682132
WhatsApp: +86 18182667606
Website: www.medtl.net
Address: 4266 Shanglin Road, Xi'an 710021, China

Company introduction PDF: Tianlong company profile

Image Filename and Alt Suggestions

Biolum Plus portable ATP luminometer for food plant surface sampling
File: biolum-plus-atp-luminometer-food-plant-sampling.png | Alt: Biolum Plus portable ATP luminometer for food plant surface sampling
Biolum Plus ATP system reference sheet with WiFi cloud data details
File: biolum-plus-atp-system-wifi-cloud-data.png | Alt: Biolum Plus ATP system reference sheet with WiFi cloud data details

SEO title: ATP Hygiene Monitoring System for Food Plant Cleaning Verification | Tianlong. Meta description: Biolum Plus ATP hygiene monitoring system delivers 10-second surface results in food plants, with WiFi cloud data and AOAC Research Institute certification. URL slug: /biolum-plus-atp-hygiene-monitoring-food-cleaning-verification