10-Second Portable ATP Hygiene Monitoring System with AOAC Certification

Biolum model · 10-18 mol ATP detection limit · 280 g handheld body · USB/Bluetooth data transfer

10 s/test280 gUSB + BluetoothAOAC no. 022401
Biolum ATP luminometer handheld unit front view
Biolum handheld ATP luminometer. Suggested filename: biolum-atp-luminometer-handheld-front.png
Biolum ATP hygiene system brochure reference layout
Biolum ATP system brochure reference. Suggested filename: biolum-atp-system-brochure-reference.png

Product Summary

Biolum is a portable ATP luminometer for surface and liquid hygiene monitoring. It delivers a 10-second test, a 10-18 mol ATP detection limit and automatic Pass/Caution/Fail result display. The 280 g handheld unit supports USB and Bluetooth data transfer, stores up to 10,000 results, and carries AOAC Research Institute Performance Tested Methods certification no. 022401. It is designed for indoor cleaning verification in food processing, food service, healthcare hygiene and environmental hygiene programs. Manufactured by Tianlong, founded in 1997 and exporting to 100+ countries.

Key Features

10-Second Test

One test per 10 seconds supports rapid cleaning verification.

10-18 mol ATP Limit

Low-level organic residue detection for hygiene checks.

280 g Handheld

189×70×35 mm body for portable surface checks.

USB and Bluetooth

Transfer results to computers or mobile devices.

Large Memory

256 test plans, 256 user IDs, 2,000 test programs and 10,000 results.

AOAC Certified

Research Institute Performance Tested Methods no. 022401.

Technical Specifications

Detection limit10-18 mol ATP
Detection time10 s/test
Weight280 g
Dimensions189×70×35 mm
CommunicationUSB, Bluetooth
Memory256 test plans; 256 user IDs; 2,000 test programs; 10,000 results
Power supplyRechargeable battery
Operating temperature5–40°C
ConsumablesQuickSwab, LiquSwab
Result displayAutomatic Pass / Caution / Fail
CertificationAOAC Research Institute Performance Tested Methods no. 022401 through 31 December 2026
Sample typesSurface and liquid hygiene monitoring

Models and Options

This page covers the Biolum model. Tianlong's ATP hygiene portfolio also lists Biolum Plus and Biolum Pro systems; request current specifications for those configurations. Compatible consumables include QuickSwab and LiquSwab. A calibration swab and a data management platform are listed as matched equipment.

Materials and Structure

The documented structure is a handheld instrument measuring 189×70×35 mm and weighing 280 g. It uses a rechargeable battery and supports USB and Bluetooth communication. The operating temperature range is 5–40°C. Confirm enclosure and material details with Tianlong for project requirements.

Applications

Food Processing

Routine surface and equipment checks plus cleaning process verification.

Healthcare Hygiene

Indoor hygiene monitoring for surfaces and equipment.

Food Service

Cleaning verification for food service environments.

Environmental Hygiene

Routine surface hygiene monitoring.

Customization

The available documentation lists QuickSwab and LiquSwab consumables and a data management platform as matched equipment. Project-specific configuration, branding or OEM requirements are not detailed in the source materials. Contact Tianlong to confirm options for your facility.

FAQ

What is the detection limit of the Biolum ATP system?

The documented detection limit is 10-18 mol ATP.

How long does one test take?

The Biolum delivers 10 seconds per test.

How are results transferred and stored?

Results transfer via USB and Bluetooth. Memory supports 256 test plans, 256 user IDs, 2,000 test programs and 10,000 results.

Which consumables are compatible?

QuickSwab and LiquSwab consumables are supported. A calibration swab and data management platform are listed as matched equipment.

Is the Biolum ATP system certified?

Yes. AOAC Research Institute Performance Tested Methods certification no. 022401 covers the Tianlong Biolum Portable ATP Hygiene Monitoring System, luminometer and matched ATP test swabs, valid through 31 December 2026.

Where can the system be used?

For indoor hygiene monitoring of surfaces and equipment in food processing, food service, healthcare hygiene and environmental hygiene. Operating temperature is 5–40°C.

What power source does it use?

The Biolum uses a rechargeable battery.

Inquiry Information

Email: inquiry@medtl.com · Telephone: +86-29-82682132 · WhatsApp: +86 18182667606

Address: 4266 Shanglin Road, Xi'an 710021, China · Website: www.medtl.net

Image Filename and Alt Suggestions

  • biolum-atp-luminometer-handheld-front.png — Alt: Biolum ATP luminometer handheld unit front view
  • biolum-atp-system-brochure-reference.png — Alt: Biolum ATP hygiene system brochure reference layout

Page SEO Metadata

SEO Title

10-Second Portable ATP Hygiene Monitoring System with AOAC Certification

Meta Description

Biolum portable ATP hygiene monitoring system: 10-second surface and liquid tests, 10^-18 mol ATP sensitivity, USB/Bluetooth data transfer and AOAC certification.

URL Slug

biolum-portable-atp-hygiene-monitoring-system

H1

10-Second Portable ATP Hygiene Monitoring System with AOAC Certification