| Type | UQDB02 Blind-Mate Sockets; UQDB04 Blind-Mate Sockets; UQDB06 Blind-Mate Sockets; UQDB08 Blind-Mate Sockets; UNF Thread UQDB Sockets; OCP UQDB Female Couplings; AI Server Liquid Cooling Sockets; Server-to-Manifold Blind-Mate Connectors | Model | JY-UQDB-02B-01N, JY-UQDB-04B-01N, JY-UQDB-06B-01N, JY-UQDB-08B-01N |
| Params | Product Name: OCP UQDB Blind-Mate Quick Disconnect Socket (Female) for AI Server Liquid Cooling Manufacturer: JINGYE Fittings (Ningbo Jingye Fluid Fittings Co., Ltd.) Sizes: UQDB02, UQDB04, UQDB06, UQDB08; four threaded socket SKUs. Configuration: Female flat-face valved blind-mate socket with UNF male threaded end. 1. Models and Product Structure UQDB02: JY-UQDB-02B-01N; 9/16-18 UNF-2A; HEX 17 mm. UQDB04: JY-UQDB-04B-01N; 3/4-16 UNF-2A; HEX 19 mm. UQDB06: JY-UQDB-06B-01N; 7/8-14 UNF-2A; HEX 24 mm. UQDB08: JY-UQDB-08B-01N; 1-1/16-12 UNF-2A; HEX 27 mm. Socket threads differ from UQDB plug threads. 2. OCP UQDB Blind-Mate Interface Interface: OCP UQDB-oriented blind-mate female connection for a corresponding same-size UQDB male plug. Operation: Engages during server tray insertion without manual coupling access. Construction: Valved flat-face low-spill coupling. UQDB blind-mate and UQD hand-mate interfaces are different families. 3. Dimensions and Mounting Envelope UQDB02: A/B/C = 33.62/23.62/19.0 mm. UQDB04: A/B/C = 39.50/28.50/21.5 mm. UQDB06: A/B/C = 43.75/31.75/27.5 mm. UQDB08: A/B/C = 51.56/35.56/31.0 mm. A/B/C follow JINGYE catalog drawings. Check installation depth, port sealing and panel clearance. 4. Working Pressure and Temperature JINGYE catalog working pressure: 0 ~ 100 psi (0 ~ 6.9 bar). Catalog operating temperature: -55°C ~ +125°C, depending on seal, coolant and configuration. The complete liquid cooling circuit is limited by the lowest-rated coupling, port, seal, hose or manifold component. Verify burst ratings by paired testing. 5. Blind-Mate Alignment and Docking Evaluate radial offset, angular misalignment, axial engagement travel, guide rails/pins, mounting stiffness and floating versus fixed mount arrangements. Measure mating forces using actual plug/socket and rack hardware. Misalignment limits and allowable mating loads depend on the approved installation and are not inferred from another manufacturer's design. 6. Flow, Pressure Drop and Leakage Flow performance: Evaluate coupled-pair Cv and pressure-drop curves versus flow rate, coolant viscosity and temperature. Leakage testing: Coupled-state leakage, disconnected shutoff leakage, per-cycle coolant loss and air inclusion after connection. UQDB02/04/06/08 flow and spillage requirements vary by design; UQD hand-mate values must not be transferred to UQDB. Record mating plug, fluid and test conditions. 7. Materials, Seals and Coolants Standard body material: SUS304 stainless steel; optional SUS316L for suitable projects. Seals: Peroxide-cured EPDM or FKM (Viton), selected for chemical and thermal compatibility. Fluids: Deionized water (DI water), propylene glycol/water (PGW), ethylene glycol/water (EGW), and approved single-phase coolant mixtures. Assess corrosion, seal swelling, additives and coolant cleanliness. Catalog salt spray resistance: 96 hours. 8. Durability and Quality Control Quality Management: ISO 9001:2015. JINGYE UQDB series catalog reference: 5,000 mating cycles; verify the selected socket/plug pair and specified test conditions. Inspection: UNF thread gauging, mating-face geometry, valve travel, seals, flat-face condition, cleanliness, visual quality and critical dimensions. Qualification may include helium leakage, pressure, fluid loss, thermal cycling, vibration, repeated docking and post-cycle sealing checks. 9. Manufacturing and OEM Integration Precision CNC manufacturing and drawing-based customization for threaded ends, stainless steel options, elastomer grades and mounting arrangements. Review interface drawings, manifold layout, counterpart plug and tolerance stack-up. Alternative-source projects can include dimensional comparison, sample mating, functional testing and batch inspection documentation. 10. Applications and Procurement Applications: AI/GPU server trays, HPC, direct-to-chip (D2C) cooling, rack manifolds, coolant distribution modules and modular data center coolant loops. RFQ: UQDB size, JY part number, port dimensions, mating plug, coolant and concentration, working pressure/temperature, target flow, mounting tolerance, cycle-life target, order quantity and test requirements. | Material | Primary Material: Stainless Steel SUS304, suitable for precision-machined OCP UQDB blind-mate female sockets used in AI server liquid cooling systems. Optional Materials: Stainless Steel 316 / 316L for enhanced corrosion resistance and selected coolant applications. Sealing Materials: Peroxide-cured EPDM or FKM, selected according to coolant chemistry, operating temperature, and sealing requirements. Coolant Compatibility: Deionized water (DI Water), propylene glycol/water (PGW), ethylene glycol/water (EGW), and compatible single-phase coolant mixtures. Wetted Components: Stainless steel body, valve components, and precision-machined flat-face sealing surfaces. Threaded Connection: Stainless steel female UQDB socket with UNF male-thread termination. Material Selection: Based on coolant compatibility, pressure, temperature, seal durability, corrosion resistance, and blind-mate requirements. |
| Applicable Industry | AI & GPU Server Cooling: AI servers, GPU clusters, accelerator modules, and high-density liquid-cooled computing. Server-to-Manifold Cooling: UQDB female sockets for blind-mate connections between server trays and rack coolant manifolds. Direct-to-Chip Liquid Cooling: CPU/GPU cold plates, D2C cooling loops, and serviceable coolant circuits. HPC & Supercomputing: Liquid-cooled HPC clusters, supercomputers, and modular computing equipment. Rack-Level Cooling: Rack manifolds, coolant supply/return lines, and blind-mate docking interfaces. Liquid Cooling Equipment OEMs: Server manufacturers, rack cooling integrators, and thermal management equipment suppliers. Data Center Maintenance & Upgrades: Server tray replacement, modular upgrades, UQDB socket servicing, and coolant circuit maintenance. | ||
JINGYE Fittings manufactures OCP UQDB blind-mate quick disconnect sockets for AI server liquid cooling in Ningbo, China. We serve server OEMs, rack cooling integrators and manifold manufacturers. Key Product Advantages: 1. Four UQDB Sizes and Four Actual SKUs UQDB02: JY-UQDB-02B-01N, 9/16-18 UNF-2A, HEX 17 mm. UQDB04: JY-UQDB-04B-01N, 3/4-16 UNF-2A, HEX 19 mm. UQDB06: JY-UQDB-06B-01N, 7/8-14 UNF-2A, HEX 24 mm. UQDB08: JY-UQDB-08B-01N, 1-1/16-12 UNF-2A, HEX 27 mm. Female sockets with male-thread ends, distinct from UQDB plugs. 2. OCP UQDB Blind-Mate Female Interface The UQDB female socket connects to a corresponding same-size UQDB male plug during server tray insertion. This enables service connections without manual coupling access. UQDB blind-mate and UQD hand-mate are distinct connector families; mating compatibility is checked for the selected pair. 3. Server-to-Manifold Docking Integration Designed for modular AI server trays, rack manifolds and liquid cooling distribution blocks. Integration review considers connector orientation, available mounting envelope, insertion depth, guide rails or alignment pins, and withdrawal clearance. Evaluate socket and plug as one docking system. 4. Alignment, Floating Mounts and Mating Force Blind-mate design involves radial and angular offsets, axial engagement travel, fixed or floating mounting provisions and insertion/withdrawal forces. Alignment limits depend on mating geometry and rack hardware. A 1 mm radial offset is an industry comparison reference, not a universal JINGYE rating. Verify offsets and forces in assembly trials. 5. UNF Threaded Port Connections Four UNF male-thread terminations support equipment-side installation: 9/16-18, 3/4-16, 7/8-14 and 1-1/16-12. Verify the mating port standard, sealing arrangement, thread engagement and tightening procedure. Port sealing is separate from UQDB face sealing. Socket threads differ from the same-size UQDB plug series. 6. Flat-Face Low-Spill Valve Construction Valved flat-face construction helps limit coolant release and air entry during disconnect and reconnection. Relevant qualification tests include connected leakage, disconnected shutoff leakage, fluid loss per cycle and air inclusion. Results depend on the matched pair, coolant and pressure; UQD values do not apply to UQDB. 7. Flow, Pressure and Temperature Engineering JINGYE catalog working pressure is up to 100 psi (6.9 bar), depending on configuration. Coupled-pair Cv, pressure-drop curves, target coolant flow and burst performance should be validated with the intended mating plug. Catalog temperature: -55°C ~ +125°C, dependent on seal and fluid. The complete circuit rating is limited by its lowest-rated component. 8. Stainless Steel and Cooling Fluid Compatibility The standard socket body uses SUS304 stainless steel, with SS316/316L options for suitable projects. EPDM or FKM seals can be selected for compatible DI water, propylene glycol/water and ethylene glycol/water coolant mixtures. Material evaluation includes glycol concentration, corrosion, additives, elastomer swelling and cleanliness of wetted surfaces and valve components. 9. Mating Durability and Quality Inspection JINGYE's UQDB series catalog lists 5,000 mating cycles; qualification depends on the selected plug/socket pair and test conditions. ISO 9001:2015 quality management supports checks of UNF threads, mating dimensions, valve movement, flat sealing faces, surface finish and cleanliness. OEM testing may include repeated docking, insertion force monitoring, vibration, thermal cycles, pressure integrity and post-cycle leakage. 10. OEM Customization and Second-Source Qualification JINGYE Fittings supports precision CNC manufacturing, customer drawings, threaded-end options, stainless steel grades, seal compounds and customized packaging. OEM projects can review mounting tolerance stack-ups, fixed/floating installation, mating plugs and inspection records. Customer-supplied samples or drawings support dimensional comparison, physical cross-mating tests and verified alternative-source procurement. 11. AI Server and Data Center Applications UQDB sockets serve AI/GPU server trays, HPC clusters, direct-to-chip cold plates, rack manifolds, coolant distribution modules and modular liquid cooling loops. JINGYE supports samples, mixed-SKU orders, OEM qualification and repeat production.

OCP UQDB Blind-Mate Quick Disconnect Socket (Female) for Data Center Liquid Cooling